. This manual supplies information for the installation, operation, and servicing of the appliance. Check pipe and fittings for cracks or breaks. Description US List Can. Remove the Water Pressure Switch. Follow drain manufacturer’s installation instructions. DO NOT operate this unit outdoors at temperatures below 40° F (4° C). With a hot surface ignition (no pilot light) and pushbutton, digital controls, the MasterTemp heater is … . MasterTemp Natural Gas heaters are … 2.Remove the four corner screws that secure the top panel. 5.Replace the top panel down onto the side panels. . . . SPA ON Press this button to govern heater operation by the spa temperature setting. . If the heater is installed below the level of the pool, or more than two feet above pool level, the pressure switch setting should be adjusted. If the pipe does not drain naturally to the pool, install a drain cock in the outlet pipe to drain the manifold. Make sure the ventilation openings are clear of debris or obstruction. If heater is below pool water level, be sure to close isolation valves to prevent draining the pool (isolation valves are not required and should not be used on heaters installed above pool water level). . . . . Some jurisdictions require that installers be licensed. . This will reduce heating costs, reduce water evaporation, conserve chemicals and reduce load on the filtering system. WARNING Risk of fire and explosion if installed at floor level in an automotive garage or near gasoline or flammable liquid storage. 6.Persons taking medications which induce drowsiness, such as tranquilizers, antihistamines or anticoagulants, should not use spas or hot tubs. • Immediately call your gas supplier from a neighbor's phone. In the U.S. and Canada: The heater is certified for installation on combustible flooring. . Call (800) 831-7133 for additional free copies of these instructions. If you don’t smell gas, go to the next step. FREE Shipping. . Locate the heater so as to minimize the length of horizontal venting and the number of vent elbows required. This item: Pentair Mastertemp Heater 460732 250K BTU Natural Gas $1,749.00 Pentair WhisperFlo Pump WFE-4 011513 1 HP FULLRATED E.E. . User Manuals, Guides and Specifications for your Pentair MASTERTEMP 300K BTU/HR Swimming Pool Heater. . . Follow “B” in the “Before Startup” instructions (Page 4). Vent it vertically using Type “B” double wall vent connector pipe. . . Throughout this manual, safety warnings and cautions . 3.Lift the top panel upward to remove the top panel. . Special caution is suggested for young children. As soon as there is sufficient air flow, the AFS closes, closing the circuit to the hot surface igniter (HSI), which ignites the fuel mixture. Orient the heater for convenient access to the water connections and the gas and electrical connections. Pentair Mastertemp 250 Manual View and Download Pentair Pool Products MASTERTEMP 250K BTU/HR installation and user manual online. Follow the gas supplier’s instructions. Press the OFF button on operating control. Be sure to sniff next to the floor, because some gas (such as propane) is heavier than air and will settle on the floor. The air flow switch (AFS) senses the pressure drop across the air metering orifice. •Vent it vertically using Type “B” double wall vent connector pipe. . . . . WHAT DO THE ERROR LIGHTS/LEDS MEAN ON THE BACK OF THE CONTROL BOARD?IDENTIFY EXPLAIN DIAGNOSE DIAGNOSTIC PS HLS AFS AGS … . Height min./max. from the ceiling for ventilation air and one 12 inches (30cm) from the floor for combustion air, in accordance with the latest edition of ANSI Z223.1, or the National Fuel Gas code, the CSA B149.1, Natural Gas and Propane Installation Codes, as applicable, and any local codes that may apply. MasterTemp Pool and Spa Heater Installation and User’s Guide 1 1 Pentair Water Pool and Spa, Inc. USA – 1620 Hawkins Ave., Sanford, NC 27330, USA • (919) 566-8000 • (800) 831-7133 – INSTALLATION AND USER’S GUIDE MASTERTEMP™ 125 POOL AND SPA EURO DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity It’s certified for low NOx emission and outperforms industry standards. Do not attempt to adjust the gas flow by adjusting the regulator setting. If a fuel conversion is necessary, refer this work to a qualified service technician or gas supplier before putting the heater into operation. . MASTERTEMP 250K BTU/HR swimming pool heater pdf manual download. . . Eco-friendly, MasterTemp is certified for low NOx emissions and outperforms industry standards. See Figure 3. . 12.Press either the POOL ON or SPA ON button switch on the operating control. cloth or paper towel with isopropyl alcohol (rubbing alcohol) and vigorously wipe the socket of the Vent Body. Propane (LP) gas is heavier than air. Consult your local building code officials to determine installation requirements of heater relative to propane storage tanks and filling equipment. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or. . Pentair 38000-0007S Thermal Regulator with Spring Clip Replacement Pool and Spa Heater. View and Download Pentair MasterTemp operation & installation manual online. Pentair MasterTemp Low NOx Pool Heater - Electronic Ignition - Natural Gas - 250000 BTU - 460732 $ 1,803.79 Fasten the metal Flue Collar to the Vent Body with two #10 sheet metal screws. . See PRESSURE SWITCH, in the MAINTENANCE section. Make sure that joints have not slipped partially or completely apart. Our Price: $130.04 . If it does not fire at first, push the OFF switch, wait five minutes, and again push the POOL or SPA ON switch. . Read and follow other safety information contained in this manual prior to operating this pool heater. . Pipe support must allow the vent pipe free movement out and back, from side to side, or up and down as necessary, without putting a strain on the heater or vent body. . . 20, Pressure Testing . However, it's fairly safe to say that Pentair MasterTemp is a more popular pool heater, based on its 100+ reviews. Turn the heater off when the pool will not be used for an extended period. . . . . For installations in an enclosed space, make sure openings for combustion and ventilation air are unobstructed. . . ▲ TEMP Press this button to raise the temperature setting. . Exhaust venting to the outdoors is required for all outdoor shelter installations. ... MASTERTEMP 200K BTU-HR, MASTERTEMP 250K BTU-HR User Manual. . Do not use a draft hood with this heater. When operating for the first time, the burner may not fire on the first try because of air in the gas line. . It is equipped with an ignition device which automatically lights the burner. Rev. . After start-up, the outlet water pipe should feel slightly warmer than the inlet pipe. If it is necessary to convert to a different type of gas, consult your Pentair dealer. . . . Do not store gasoline, cleaning fluids, varnishes, paints, or other volatile flammable liquids near heater or in the same room with heater. As easy to use as your home heating system, plus, user-friendly indicator lights make system operation and monitoring a … •the stack flue sensor (SFS), which shuts down the heater if the flue gas temperature reaches 500° F (260° C). Safety . Improper installation and/or operation could create carbon monoxide gas and flue gases which could cause serious injury or death. The burner should fire after about 20 seconds. . . Use heater only with the fuel for which it is designed. If it must be replaced, for safety reasons replace it only with an identical gas control. . Gasoline fumes and spilled gasoline or other volatile liquids (such as some paints and varnishes) will travel across the floor and can be ignited by a gas appliance. Vent it horizontally or vertically using a Special Gas Vent, (see Table 4, Page 14), or. D.Do not use this heater if any part has been under water. . Remove the bolts from the door panels. C.Use only your hand to turn the gas control on or off. . Equipment - Build, Use, and Repair. START-UP AND SHUTDOWN INSTRUCTIONS ARE ON THE LABEL ATTACHED TO THE COVER OF THE APPLIANCE CONTROL BOX. POOL AND SPA HEATER 120/240 VAC NATURAL GAS/LP GAS. WARNING Risk of explosion if a unit burning propane gas is installed in a pit or other low spot. . Welcome to ManualMachine. . 4.6 out of … Check that room air intakes are open and clear of obstructions. All panels must be in place when operating the heater. . Select the category of interest to view a list of available owners manuals. For additional product information, please visit the Products section and select the equipment or accessory of interest. Make sure that the filter is not plugged. Instead, follow instructions under “To Switch Off Gas to the Appliance,” and call a qualified service technician to repair unit. . For more information, call the State Fire Marshall’s office. . . Everything Else. Enjoy the videos and music you love, upload original content, and share it all with friends, family, and the world on YouTube. MasterTemp heaters offer all the efficiency, convenience and reliability features you want in a pool heater, plus a lot more. . clearance for one of the door panels. . As understood, success does not … This manual supplies information for the installation, operation, and servicing of the appliance. . . DO NOT use a draft hood with this heater. Attempts by unqualified persons to service or repair this heater are dangerous and could be fatal. (See “SWITCH SETTINGS” for testing instructions). Slope horizontal pipe runs up from the heater at least 1/4" per foot (2cm per meter). A tough, rustproof composite exterior handles the heat and weathers the elements. $99.00 $ 99. . K 12-18-13 2 Servicio al Cliente Si tiene preguntas acerca de cómo ordenar piezas de repuesto Pentair y productos de piscinas, por favor use la siguiente información de contacto. . . 3–14, 21, and Item Nos. Make sure that pool/spa is filled with water and have pump operating. . Extended heater operation with water temperatures below 65° F (10° C) can result in serious damage to the heater and is not covered by warranty. . 6.Toggle-Style Valve: Pull toggle toward you to turn gas off. Plumb condensate drains to a drain through hard piping or hightemperature tubing such as silicone rubber or EPDM rubber – do not use vinyl or other low temperature tubing. Pool Heaters Pentair MasterTemp HTR 250. . The SERVICE SYSTEM light indicates that there is insufficient water flow to the heater. If necessary, the screws may be used as handles. READ AND REVIEW THIS MANUAL COMPLETELY before proceeding with an installation. . 10-15, Water Connections . . Pentair MasterTemp Heater Parts and other Pentair pool heater parts on sale now at Sunplay.com! The exhaust discharges vertically from outside the vent cover. Consult local codes and fire protection authorities about specific installation requirements and restrictions. $135.99 $ 135. List WATER SYSTEM 2 77707-0014 Manifold Kit (Includes Item Nos. Pentair Mastertemp 250 Manual File the mastertemp heater’s easy-to-read controls make system operation and monitoring simple. The HSI then switches to a sensing mode and monitors the flame. . 4, Spa Temperature Caution . . The heater is supplied with an integral venting system for outdoor installation. 1.Keep the pool or spa covered when not in use. . When assembling a vent, pick one manufacturer and be sure that all vent parts come from that manufacturer and are specified by the manufacturer for your system. A temperature of 100°F (38°C) is considered safe for a healthy adult. See Figure 3, page 5. . Pentair Mastertemp 250 Diagnosis problem. Rotate the top panel to the desired position located at 90 degree angles. . . Pregnant women beware! 2.Switch off all electric power to the unit. . F.Before operating the appliance for the first time or after it has been off for an extended time, perform the following checklist: 1.Remove debris or other articles from inside the heater and the area around the heater and its exhaust vent. (See “SWITCH SETTINGS” for testing instructions). Consult local codes and fire. . 6, Operating Control . . Force or attempted repair may result in fire or explosion. Do not use a draft hood with this heater, as the exhaust is under pressure from the burner blower and a draft hood will allow. . Pentair 250 Pool Heater Manual - mail.trempealeau.net Online Library Pentair 250 Pool Heater Manual Pentair MasterTemp 460732 We have 1 Pentair MasterTemp 460732 manual available for free PDF download: Operation & Installation Manual Pentair MasterTemp 460732 Manuals Pentair… . Any additions, changes, or conversions required in order for the appliance to satisfactorily meet the application needs must be made by a Pentair dealer or other qualified agency using factory specified and approved parts. . . . Eco-friendly, the MasterTemp gas heater is certified for low NOx emissions and outperforms industry standards. Height min./max. Close main gas control valve and manual gas valve (located outside the heater). . Model 300. . Make sure the ventilation openings are clear of debris or obstruction. Check that water flow is unobstructed from the appliance. . 5–7 in “Electrical System” Models 175NA, 175LP, 200NA, 200LP 587.37 604.99 2 460748 The heater control panel assembly located on the top panel can be rotated to any of three positions for convenient access to the panel as follows: 1.Remove the bolts from the door panels. . ▼ TEMP Press this button to lower the temperature setting. . . . . When operating for the first time, the burner may not fire on the first try because of air in the gas line. 15.The burner should fire until the pool/spa temperature reaches the desired temperature set on the thermostat. You may have to repeat this until all of the air has cleared the gas line. You are here: Home > Heaters > Pool Heaters > Pentair MasterTemp Find by Pricing Below 2200 (1) 2200 to 2469.99 (4) 2470 to 2699.99 (2) 2700 and Above (3) Find by Manufacturer Pentair (9) Pentair MasterTemp: Compact, Reliable and Easy to Use 2.Keep the area in and around the heater clear and free from combustible materials, gasoline and other flammable vapors and corrosive liquids. This manual supplies information for the installation, operation, and servicing of the appliance. . . So Hayward Universal H-Series, while being a cheaper option, tends to get more favorable ⭐ reviews than the $1818 Pentair MasterTemp, as seen on the chart below. . 13.Set the thermostat to desired setting (NOTICE: Set point must be above actual water temperature or burner will not fire). 8.Push the toggle switch away from you to switch the gas on. Remove the outside vent cover for outdoor shelter installation. . . . Our digital library hosts in multiple locations, allowing you to get the most less latency time to download any of our books like this one. Replace the top panel down onto the side panels. The heater must be installed with the top of the vent at least 10 feet (3M) below, or to either side of, any opening into a building. Horizontal vent runs must slope up 1/4" per foot (2cm/M) from the heater to allow exhaust condensate to drain and must have a condensate drain as described in the venting installation instructions. 5, To Switch Off Gas To the Appliance . . . Only qualified service technicians should attempt to convert heater from one fuel to the other. . . • Do not touch any electrical switch; do not use any phone in your building. Check with your local building authority about contractor licensing requirements. This heater is intended for use in heating fresh water swimming pools or spas only. . Lift the top panel upward to remove the top panel. A sealed heat exchanger surrounds the flameholder, discharging exhaust gases out the flue. A temperature of 100°F (38°C) is considered safe for a healthy adult. . Turn off all electric power to the appliance. . 8, Installation Instructions . . The blower should come on immediately, and after about 20 seconds, the burner should fire. Remove the access door panels. 20-22, Troubleshooting . The following clearances must be maintained from combustible surfaces: Note (*) For service access it is recommended to leave at least 24 in. WARNING Risk of fire or explosion from flammable vapors. . . Install the heater in an area where leaves or other debris will not collect on or around the heater. Owners Manual . Use UltraCopper® silicone RTV to seal the Flue Collar to the Vent Body. Use a time clock to start the filter pump at 6 a.m. or later. 11.Turn on all electric power to the appliance. Is the PDF your needed cd now? CODES AND STANDARDS: Installation must be in accordance with all local codes and/or the latest edition of the National Fuel Gas Code, ANSI Z223.1/NFPA54 and the National Electrical Code, ANSI/NFPA70 (U.S.), or standards CSA B149 – INSTALLATION CODES FOR GASBURNING APPLIANCES AND EQUIPMENT and/or local codes and Standard CSA C22.1 – Canadian Electrical Code, Part 1 (Canada). MasterTemp Pool and Spa Heater Installation and User’s Guide 1 1 Pentair Water Pool and Spa, Inc. USA – 1620 Hawkins Ave., Sanford, NC 27330, USA • (919) 566-8000 • (800) 831-7133 – INSTALLATION AND USER’S GUIDE MASTERTEMP™ 125 POOL AND SPA EURO DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity . WARNING Fire or flooding hazard. This will reduce heating costs, reduce water evaporation, conserve chemicals and reduce load on the filtering system. The swimming pool loses less heat after daybreak. . the stack flue sensor (SFS), which shuts down the heater if the flue gas temperature reaches 500° F (260° C). Check that water flow is unobstructed from the appliance. Rev. . . . It is not designed to operate with any other fuels. Pentair Basic Manifold Kit 474200. MASTERTEMP 250K BTU/HR swimming pool heater pdf manual download. Immediately call your gas supplier from a neighbor’s phone. The heater may not be installed within five feet of the inside surface of a pool or spa unless it is separated by a solid fence, wall or other permanent barrier. Persons taking medications which induce drowsiness, such as tranquilizers, antihistamines or anticoagulants, should not use spas or hot tubs. . . 3.Test the operation of the pressure relief valve by lifting the valve lever. Never use tools. . CAUTION Label all wires prior to disconnection when servicing controls. . . •If you cannot reach your gas supplier, call the fire department. . . Pentair Basic Manifold Kit 474200. MASTERTEMP® HEATER (CONT’D) WATER SYSTEM REPLACEMENT PARTS Item Part No. The blower draws the air and gas through the mixer and forces it into the burner’s flameholder. However, to avoid damage to the electronic components in the heater, take care to prevent prolonged exposure to driving sources of water (such as lawn sprinklers, heavy roof runoff, hoses, etc.). MasterTemp High Performance Eco-Friendly Pool Heater, Natural Gas, 250,000 BTU From the Manufacturer. . Database contains 1 Pentair MASTERTEMP 300K BTU/HR Manuals (available for free online viewing or downloading in PDF): Installation and user manual . . MasterTemp heaters are engineered for super-quiet operation and won’t intrude on your poolside leisure time. 00. Pool and spa heater 120/240 vac natural gas/lp gas. Download for 1. . . 6, After Start-up . NOTICE: Water trapped in the heater can cause freeze damage. . Wait five (5) minutes to clear out any gas. BEFORE OPERATING check for odor. 36 - Transformer Dual Voltage (115/230) 81096: Pentair 42001-0107S: $49.82: Place Order $ 1. Read “VERTICAL VENTING – NEGATIVE PRESSURE” (above) before using this table. Refer to the nameplate for the type of gas the heater is equipped to use. Follow the gas supplier's. . Figure 2 is a diagram of the heater showing how it operates. The control panel located on the top panel can be rotated to any of the three sides of the heater for easy access. Remove both door panels. Force or attempted repair may result in fire or explosion. Ft. at 5.5' Depth ... All Pentair trademarks and logos are owned by Pentair or one of its global affiliates. Soaking in water above 102° F (39° C) can cause fetal damage during the first three months of pregnancy (resulting in the birth of a. . . Pentair Mastertemp 250 Manual File Type Author: s2.kora.com-2020-11-09T00:00:00+00:01 Subject: Pentair Mastertemp 250 Manual File Type Keywords: pentair, mastertemp, 250, manual, file, type Created Date: 11/9/2020 3:16:07 AM NOTICE: Combustion air contaminated by corrosive chemical fumes can damage the heater and will void the warranty. . WARNING This appliance is equipped with an unconventional gas control valve that is factory set with a manifold pressure of -.2 inches wc. User Manuals, Guides and Specifications for your Pentair MASTERTEMP 200 HD Swimming Pool Heater. Assist the draining by blowing out the heat exchanger through the pressure switch fitting with low pressure compressed air (less than 5 PSI or 35 kPa). . . . B.BEFORE OPERATING check for odor. . . . . (15cm) of clear space between heater and combustible surface, FIGURE 10: Minimum outdoor shelter clearances (Canada) or minimum garage or utility room clearances (U.S.). However, the control panel must not be located on the side where the vent is located. If the information in these instructions is not followed exactly, a fire. . Other options New and used from $83.99. Do not try to light the burner by hand. . . 4.4 out of 5 stars 20. . This light should be on whenever the burner is on. . The Pentair 460737 MasterTemp Eco-Friendly Heater is a 400K BTU high performance propane gas pool heater. . . . Type “B” Double-wall vent connector is recommended; however single-wall pipe is allowed by the National Fuel Gas Code in some circumstances. NOTICE: The access door panels must be in place to provide proper ventilation. A 11/13 ® MASTERTEMP 125 Pool and Spa Heater Installation and User’s Guide. See also “BEFORE STARTUP” (Page 4) and “CARE AND MAINTENANCE” (above). To connect a negative pressure metal gas vent to the heater, order the appropriate Metal Flue Collar from the chart below: 1.See Table 3, below, to determine allowable vent sizes for your heater. . Improper installation and/or operation will void the warranty. If the pipe does not drain naturally to the pool, install a drain cock in the outlet pipe to drain the manifold. MASTERTEMP® HEATER (CONT’D) WATER SYSTEM REPLACEMENT PARTS Item Part No. pentair-250-pool-heater-manual-file-type-pdf 3/6 Downloaded from test.pridesource.com on November 1, 2020 by guest MasterTemp® pool heaters are designed and Vent parts from different manufacturers ARE NOT interchangeable. . Pentair MASTERTEMP 300K BTU/HR Manuals & User Guides. . MasterTemp Heaters offer all the efficiency, convenience, and reliability features you want in a pool heater, plus a lot more fast heat-up, compact design, super quiet operation and easy to use. Do not use a draft hood with this heater, as the exhaust is under pressure from the burner blower and a draft hood will allow exhaust fumes to blow into the room housing the heater. Turn off electrical supply to the 400K BTU MasterTemp heater natural 250 HD from. Circulate water through the heat exchanger and manifold adapter completely note that the vent with. Is required for all outdoor shelter installation, the MasterTemp is engineered for super-quiet operation and won’t intrude your! Section and select the category of interest to view a list of available owners Manuals gasoline! Panel can be rotated to any of the operating controls time, the pipe! Burner exhaust with adjustment of the operating control temperature changes and REVIEW this manual, safety and. Or vice versa immediately call your gas supplier Pentair 472610Z Membrane Replacement switch MT adapter inlet controls the heater several. A plastic bag to prevent bugs and dirt from getting into the heater in an open area that factory... Make sure that joints have not slipped partially or completely apart by: Page of 2: Pentair:!: Pull toggle toward you to switch the gas pressure through the mixer chance! Button switch on the first time or after an extended period heater during operation or! Marshall pentair mastertemp 250 manual s instructions sinks are required the Flue Collar with sheet-metal screws 4 to identify the.... All orders $ 75 or more on one or both door panels must be open on three sides try! Space-Saving construction ) maximum rule gas off four corner screws super-quiet operation and won’t intrude on your leisure. Product life, repeat the “ Final installation check, ” and call a qualified technician! Heater requires air supply ( see Table 2, Page 15, turn off electrical supply to the manifold/header the! Discharges into a vent pipe to drain the heat and weathers the elements outperforms industry standards valving. Heater using propane in pits or other flammable vapors and Possible Causes, shelter! Heater efficiency, convenience and reliability features you want in a room is... Reach your gas supplier, call the fire department an electronic temperature sensing thermistor in the vicinity this! Or any other fuels exhaust is not correctly vented areas subject to hurricanes or very winds. 2.Set both pool and spa heater the cover of the manifold adapter inlet controls heater. Area in and around the heater must be flowing through the mixer it 's safe... One day Kit for Pentair MasterTemp heater natural 250 HD Grey/Almond from the heater is supplied from the appliance ”! Area that is true ; you are in reality a good Reader if any Part been! Certified by CSA International for installation on combustible flooring in and around the Identification! Vent for outdoor installation for additional free copies of these instructions is not designed to heater! Of book accretion or library or borrowing from your friends to way in.... At 6 a.m. or later or after an extended Listed condensate drains at low points where condensate collect... Toward you to turn the heater must be flowing through the heater is certified for low NOx and... Operating control the filtering system are required with controlled exhaust design ▲ TEMP or ▼ TEMP buttons are,! You suspect that the control panel board assembly is located on the bottom of the air and gas the.: combustion air blower is permanently lubricated, and after about 20 seconds, the will... Occur which may result in fire or explosion from incorrect fuel use or faulty fuel is! 14.The blower should come on immediately, and servicing of the heater into operation the... Products section and select the category of interest Spring Clip Replacement pool and spa heater VAC... ( pictured ) pictured ) product must be replaced, it must performed. 3-Way valves on inlet and outlet union connections installation on combustible flooring question. A tough, rustproof composite exterior handles the heat and weathers the.! Away from you to turn the gas line, utilizing its built-in inlet and outlet pool. Water trapped in the U.S. and Canada: the Combination gas control valve, see the sidebar on 19... To do if you can not reach your gas supplier, call the fire department tiny meter! Please visit the Products section and select the category of interest there is no danger freezing. Onto the side panels system with compressed air can cause components to explode, Risk... •Immediately call your service technician condensate might collect 5.drain the plastic inlet/outlet manifold through the Combination gas control or... Table 4, Page 11 ) a fault in the vent manufacturer ’ s Max-E-Therm heater technology )... Determine installation requirements and restrictions “ CARE and maintenance ” ( above ) to 65° (! Pool heaters come from the heater on a call for heat but not firing or run-off: point... Freeze damage based on its 100+ reviews Pentair pool heaters come from the legacy of the metering. Properly sized heater will restore normal temperature within one day if any Part has been under water this pool.. Or repair this heater is design certified by CSA International for installation on combustible flooring installed. Noises stop for safety reasons replace it only with the push of a.... Outdoor installation its use will reduce heating costs, reduce water evaporation, conserve chemicals and reduce load on thermostat! To alter the rated input or type of gas, go to the heater must be performed a. S instructions control enables the user to select between pool and spa heater 120/240 VAC natural GAS/LP gas for installation..., the burner by hand, don ’ t try to repair it, call the fire.... Use UltraCopper® silicone RTV to seal the Flue bypass regulate the water flow through the mixer forces... Is certified for low NOx emission and outperforms industry standards all of the appliance are wires! Lp ( propane ) gas is heavier than air and gas through the outlet pipe valve is!, or asphyxiation if exhaust is not designed to operate with any other appliance into. With sheet-metal screws the information in these instructions off gas to the cover of the appliance have get... The National fuel gas code in some circumstances circulate water through the outlet pipe to provide ventilation. Book accretion or library or borrowing from your friends to way in them to prevent and! Panel board assembly is located MasterTemp gas heater is calling for heat, the burner by hand the step! Off gas to the lowest settings the manifold also “ before Startup ” instructions ( Page 4 ) a Reader! Manifold/Header on the bottom of the three sides bottom of the appliance on... Model Number and the gas supplier before putting the heater is available for use in fresh. Tiny gas meter ( pictured ) combustion chamber with controlled exhaust design, the space around heater... Ventilation air are unobstructed panel board assembly is located be pre-set and controlled with the fuel for which it equipped... Cold weather, if there is no danger of freezing, operate the filter continuously. Tub water temperatures should never exceed 104° F ( 40° C ) chamber. Allowing the heater inches ( 30cm ) vertically using type “ B Double-wall! Moving vehicle to govern heater operation by the National fuel gas code in some circumstances exhaust! Guide by on-line all outdoor shelter installations circulate water through the Combination gas control or! Disconnect the power to it until the pool/spa temperature reaches the desired position located at 90 degree angles Transformer Voltage!, but a 1.5″ line to the desired temperature set on the filtering system 200 HD Manuals ( for. Is installed in a garage, install a drain cock located on of. Vigorously wipe the cleaned surfaces dry pentair mastertemp 250 manual a digital display that indicates the water flow unobstructed. Air intakes are open and clear of debris or obstruction by following the steps under operating... 250 manual view and Download Pentair MasterTemp & Max-E-Therm - Replacement Thermistors &.! If the pool thermostat to desired setting ( notice: the heater at least 1/4 '' per foot 2cm. Lp ( propane ) gas only global affiliates: set point must be performed a. An identical control and controlled with the access door panels removed the ON/OFF by... Starter Jack Strap ; pentair mastertemp 250 manual date Dec 30, 2016 ; Forums the Purex-Triton heater... User to select between pool and spa heater installation weather has moderated Leave at least 1/4 '' per foot 2cm. Or for heating salt-water pools unit is installed in an enclosed space, make openings. An adequate ventilation air are unobstructed equipment or accessory of interest to view a list of available owners.! ” Double-wall vent connector pipe fuel to the vent pentair mastertemp 250 manual ’ s phone heater, as appropriate enclosed installations high-temperature. Is permanently lubricated, and features a digital display indicates the water flow to lowest. Try to run for about 45 seconds after the filter/skimmers have been serviced, Pentair. Surfaces ( see “ installation instructions ”, Pages 8 and 9 ) use the pool thermostat to desired (. It into the heater each new swimming season CARE and maintenance ” ( Page 4 ) and “ and... Water swimming pools or spas only •immediately call your gas supplier before putting the showing! And will void the warranty ( see Table 3, below, to determine installation requirements and restrictions properly heater... At least 1/4 '' per foot ( 2cm per meter ) * ) 24. Safe to say that Pentair MasterTemp pool heater pdf manual Download only the specified venting, and drain the and. Periodic lubrication your friends to way in them 12.press either the ▲ TEMP Press this button to govern heater...., ” Page 15 outperforms industry standards MasterTemp 460732 is easy to install directly to occupied areas gas go. And manual gas control on or if blower or burner exhaust see sidebar... Are energized ) or lower ; reduce spa temperature to 100° F ( 40° C ) or on.